MSA Pro - Proper calibration, better parts
What is MSA Pro?
MSA Pro is an application that helps organizations identify, catalog, calibrate
and study the measurement certainty of inspection, testing, and lab equipment. MSA
Pro tests both the measurement system equipment and processes to ensure that your
measurement systems produce accurate, repeatable and stable measurements.
Why use MSA Pro?
If your measurement equipment is not functioning properly, you will inevitably be
faced with expensive quality problems. In addition, ISO 9001:2008 and TS 16949:2002
require equipment measurement uncertainty to be studied. MSA Pro helps you identify,
catalog, calibrate, and study the measurement system variation and uncertainty of
your inspection, testing, and lab equipment. The power of the software is its ability
to use the statistical techniques of stability, linearity, bias, and gage repeatability/reproducibility
to gather data on frequency, measurement system variation, and uncertainty and organize
it into easily digested reports and graphs. MSA Pro is also distinct in that it
gathers information into families so you can reduce the number of MSA studies required
in your organization.
Key Features
Calibration Lab Database
MSA Pro maintains a database of all Calibration Laboratories or Agencies. The record
contains information about the agency, like name, contact address, phone number,
and email. These outside agencies may be used to calibrate the gage equipment.
Calibration Process
- Group your instruments into a particular group or type for easy management.
-
Attribute, Variable, and Master gage information can be imported into the system.
Repeatability & Reproducibility Method (R &R)
Repeatability is the variation in measurements obtained using one measurement instrument
several times on the identical characteristics of the same part.
Reproducibility is the variation in the average of the measurements made by different
appraisers using the same measuring instrument while measuring the identical characteristics
on the same part.
MSA Pro allows you to define a specific gage in each type for a particular characteristic
that needs to be analyzed. This is a unique feature of MSA Pro that reduces the
number of studies required in an organization. Also, it clearly links gage types
and gages to the R&R system study as required for each organization.
Reports & Visual Analysis (Charts)
- All instruments that need to be calibrated in the time period are shown.
-
All instruments that are not calibrated per user-defined due dates are shown.
-
All gages calibrated in the user-defined time period are shown.
- Generate a separate
report for each gage.
- Summary reports can be created to aggregate various gage
studies.
Standard graphs
- Run Chart
- Scatter Plot
- Whiskers Chart
- Error Chart
-
Comparison X-Y Plot
- X Y Plot Average
Standard reports
- Calibration History
- List of Measurement Systems
- Gage List By Time
Period
- Gage List Calibrated By Due Date
- Gage List Not Calibrated By
Due Date
- Gage List Not Completed on Time
- Gage List of External Lab Calibration